Introduction: The success of periradicular surgery depends
on the ability of root-end filling materials to provide an effective seal
between the root canal system and periapical tissues. Mineral Trioxide
Aggregate (MTA) is widely used due to its biocompatibility and sealing ability;
however, blood contamination during surgical procedures is often unavoidable
and may influence its performance. The timing of contamination, whether before
or after placement, may affect the hydration and adaptation of the material.
Objectives:
This study aimed to evaluate the effect of
blood contamination timing on the sealing ability of MTA cements used as
root-end filling materials.
Method: Sixty extracted single-rooted human premolars
were prepared, and 3 mm root-end cavities were created following root-end
resection. Samples were divided based on the material used and further
subdivided into three conditions: dry, blood contamination before placement,
and blood contamination after placement. Cavities were filled accordingly, and
microleakage was assessed using 2% methylene blue dye penetration under a
stereomicroscope. Statistical analysis was performed using one-way ANOVA followed by
Tukey’s post hoc test, with a significance level set at p < 0.05.
Result: Significant differences in microleakage were
observed in one of the tested MTA materials across the three conditions, with
greater leakage in dry conditions compared to blood-contaminated groups. No
significant difference was found between contamination occurring before and
after placement. The other material demonstrated consistent sealing ability
across all conditions.
Please enter the email address corresponding to this article submission to download your certificate.